Development of a triple GEM UV-photon detector operated in pure CF4 for the PHENIX experiment

Kozlov, A. · Ravinovich, I. · Shekhtman, L. · Fraenkel, Z. · Inuzuka, M. · Tserruya, I.

Original · EN

Results obtained with a triple GEM detector operated in pure CF4 with and without a reflective CsI photocathode are presented. The detector operates in a stable mode at gains up to 10⁴. A deviation from exponential growth starts to develop when the total charge exceeds 4 10⁶ e leading to gain saturation when the total charge is 2 10⁷ e and making the structure relatively robust against discharges. No aging effects are observed in the GEM foils after a total accumulated charge of 10 mC/cm² at the anode. The ion back-flow current to the reflective photocathode is comparable to the electron current to the anode. However, no significant degradation of the CsI photocathode is observed for a total ion back-flow charge of 7 mC/cm².