Relativity and the lead-acid battery
Ahuja, Rajeev · Blomqvist, Andreas · Larsson, Peter · Pyykkö, Pekka · Zaleski-Ejgierd, Patryk
Original · EN
The energies of the solid reactants in the lead-acid battery are calculated ab initio using two different basis sets at non-relativistic, scalar relativistic, and fully relativistic levels, and using several exchange-correlation potentials. The average calculated standard voltage is 2.13 V, compared with the experimental value of 2.11 V. All calculations agree in that 1.7-1.8 V of this standard voltage arise from relativistic effects, mainly from PbO2 but also from PbSO4.