Masaq Index
arXiv 2015-04-08 0 views

High-frame rate, fast neutron imaging of two-phase flow in a thin rectangular channel

Zboray, R. · Mor, I. · Dangendorf, V. · Stark, M. · Tittelmeier, K. · Cortesi, M. · Adams, R.

Original · EN

We have demonstrated the feasibility of performing high-frame-rate, fast neutron radiography of air-water two-phase flows in a thin channel with rectangular cross section. The experiments have been carried out at the accelerator facility of the Physikalisch-Technische Bundesanstalt. A polychromatic, high-intensity fast neutron beam with average energy of 6 MeV was produced by 11.5 MeV deuterons hitting a thick Be target. Image sequences down to 10 millisecond exposure times were obtained using a fast-neutron imaging detector developed in the context of fast-neutron resonance imaging. Different two-phase flow regimes such as bubbly slug and churn flows have been examined. Two phase flow parameters like the volumetric gas fraction, bubble size and bubble velocities have been measured. The first results are promising, improvements for future experiments are also discussed.

English translation

This paper has no Arabic translation yet. Be the first: it takes a few seconds, and the result is stored for every future reader.

Security check

Type the characters above

Up to 10 translations per person per day.